How do I calculate BTU for server room cooling?
To determine the BTU duty of the room, calculate the area of the room in metres and multiply by 337.
- Server Room Area BTU duty: Width x Length x 337.
- North Facing Window BTU: Window Area (width x length) x 165.
- South Facing Window BTU: Window Area (width x length) x 870.
Is AC required in server room?
The server rooms require reliable control on temperature and humidity so that the data storage equipment functions in an efficient manner. The customer interface/waiting areas need proper air conditioning to meet the comfort levels of the customers.
How do you calculate the heat load of a server room?
Useful BTU Cooling Formulae:
- Equipment BTU = Total wattage for all equipment x 3.5.
- Lighting BTU = Total wattage for all lighting x 4.25.
- Total Occupant BTU = Number of occupants x 400.
- Room Area BTU = Length (m) x Width (m) x 337.
- Total Heat Load = Room Area BTU + Total Occupant BTU + Equipment BTU + Lighting BTU.
How do I know what BTU my air conditioner is?
All you have to do is to multiply the length of your room in feet by the width of your room in feet, and then multiply that by 25. That will give you the BTU needed to properly cool your room. All it takes is a simple multiplication!
How do I calculate air conditioner requirements?
Calculate Size To calculate the size, simply multiply the length times the width of the room or area to be cooled. Then, as a practical number, multiply that total times 25 BTU. This allows ample cooling, whether it is a rainy, moist day or a hot, sunny, humid day. Let’s say the room is 12 feet wide by 15 feet long.
How do you calculate air conditioner cooling load?
Calculating a Home’s Cooling Load
- Determine the dimensions of the room or home that needs cooling. For a room, you can do this with a measuring tape.
- For a room, multiply its length by its width to get the square footage.
- Multiply the square footage by 20. This is the measure of the BTU cooling load of the space.
Which AC is best for server room?
Single-split air conditioners are the ideal option for server rooms as it is vital that the unit is independent from any other air conditioners that you may have in your office. Therefore, multi-split systems and VRF systems are not suitable.
How many square feet will a 8000 BTU air conditioner cool?
350 square feet
At 8,000 BTU, it has the cooling capacity for up to about 350 square feet.
How to calculate the size of a server room air conditioner?
Total Heat Load = Room Area BTU + Windows BTU + Total Occupant BTU + Equipment BTU + Lighting BTU This is the amount of cooling required so you need one or more air conditioning units to handle that amount of heat.
How to calculate the BTU of a server room?
This the summary of your server room setup. Locate this number from utility provider. Or use sample. Click next for Cost Estimate Calculation. Recommended A/C unit will be above this value. You will want to take the calculations above as estimates to give you a good idea of what your needs will be.
How to calculate heat loads and server room cooling?
Total Cooling Calculation The total cooling load is then a summation of the individual calculation as follows: Floor Area + Window + People + IT Equipment + Lighting = Total Cooling BTU required and to get the kW divide the Total Cooling BTU by 3412
What should the temperature be in a server room?
For most people, any temperature above 27˚C becomes uncomfortable for work. The recommended temperature range for a computer or server room or datacentre is 18-27˚ and ideally 18-25˚. This lower limit is recommended for any UPS systems used within the computing environment with valve regulated lead acid ( VRLA) batteries.